You must replace a flash capacity device or a magnetic disk if you detect a failure or when you upgrade it.
Before you physically remove the device from the host, you must manually delete the device from vSAN. When you unplug a capacity device without removing it from the vSAN cluster, the components on the disk are marked as absent. If the capacity device fails, the components on the disk are marked as degraded. When the number of failures of the object replica with the affected components exceeds the FTT value, the virtual machines on the disk become inaccessible. See Capacity Device Not Accessible in vSAN Cluster.
You can also watch the video about how to replace a failed capacity device in vSAN.
Prerequisites
-
Verify that the storage controllers on the hosts are configured in passthrough mode and support the hot-plug feature.
If the storage controllers are configured in RAID 0 mode, see the vendor documentation for information about adding and removing devices.
- If you upgrade the capacity device, verify that the cluster contains enough space to migrate the data from the capacity device.
Procedure
What to do next
- Add a new device to the host.
The host automatically detects the device.
- If the host is unable to detect the device, perform a device rescan.