Network Interface Cards (NICs) used in vSAN hosts must meet certain requirements. vSAN works on 10 Gbps, 25 Gbps, 40 Gbps, 50 Gbps, and 100 Gbps networks.
Ensure your hosts meet the minimum NIC requirements for vSAN Original Storage Architecture (OSA) or vSAN Express Storage Architecture (ESA).
Topology or Deployment Mode | Architecture | Support for 1 GbE NIC | Support for 10 GbE NIC | Support for NICs Greater than 10 GbE | Inter-Node Latency | Inter-Site Link Bandwidth or Latency | Latency Between Nodes and vSAN Witness Hosts | Bandwidth Between Nodes and vSAN Witness Hosts |
---|---|---|---|---|---|---|---|---|
Single Site vSAN Cluster | Hybrid Cluster | Yes (Minimum) | Yes (Recommended) | Yes | Less than 1 ms RTT. | NA | NA | NA |
All-Flash Cluster | No | Yes | Yes (Recommended) | |||||
vSAN Stretched Cluster | Hybrid or All-Flash Cluster | No | Yes (Minimum) | Yes | Less than 1 ms RTT within each site. | Recommended is 10 GbE (Workload Dependent) and 5 ms RTT or less. | Less than 200 ms RTT. Up to 10 hosts per site. | 2 Mbps per 1000 components (Maximum of 100 Mbps with 45 k components). |
Less than 100 ms RTT. 11–15 hosts per site. | ||||||||
Two-Node vSAN Cluster | Hybrid Cluster | Yes (Up to 10 VMs) | Yes (Recommended) | Yes | Less than 1 ms RTT within the same site. | Recommended is 10 GbE and 5 ms RTT or less. | Less than 500 ms RTT. | 2 Mbps per 1000 components (Maximum of 1.5 Mbps). |
All-Flash Cluster | No | Yes (Minimum) |
Deployment Type | Support for 1 GbE NIC | Support for 10 GbE NIC | Support for NICs Greater than 10 GbE | Inter-Node Latency | Inter-Site Link Bandwidth or Latency | Latency Between Nodes and vSAN Witness Hosts | Bandwidth Between Nodes and vSAN Witness Hosts |
---|---|---|---|---|---|---|---|
Single Site vSAN Cluster | No | Yes | Yes | Less than 1 ms RTT. | NA | NA | NA |
vSAN Stretched Cluster | No | Yes | Yes | Less than 1 ms RTT within each site. | Minimum 10 GbE (workload dependent) and 5 ms RTT. | Less than 200 ms RTT. Up to 10 hosts per site. | 2 Mbps per 1000 components (Maximum of 100 Mbps with 45 k components). |
Less than 100 ms RTT. 11–15 hosts per site. | |||||||
Two-Node vSAN Cluster | No | Yes | Yes | Less than 1 ms RTT within the same site. | Recommended is 25 GbE and 5 ms RTT or less. | Less than 500 ms RTT. | 2 Mbps per 1000 components (Maximum of 1.5 Mbps). |
Note: These NIC requirements assume that the packet loss is not more than 0.0001% in the hyper-converged environments. There can be a drastic impact on the
vSAN performance, if any of these requirements are exceeded.
For more information about the vSAN stretched cluster NIC requirements, see vSAN Stretched Cluster Guide.