When you configure vRealize Log Insight, you must stay at or below the supported maximums.
Item | Maximum |
---|---|
Node Configuration | |
CPU | 16vCPUs |
Memory | 32 GB |
Storage device (vmdk) | 2TB - 512 bytes |
Total addressable storage | 4 TB (+ OS drive) A maximum of 4TB addressable log storage on VMDKs with a maximum size of 2TB each. You can have two 2TB VMDKs or four 1TB VMDKs, etc. When you reach the maximum, you will need to scale outward with a larger cluster size instead of adding more disks to existing VMs. |
Syslog connections | 750 |
Cluster Configuration | |
Nodes | 12 (Primary + 11 Workers) |
Ingestion per Node | |
Events per second | 15,000 eps |
Syslog message length | 10 KB (text field) |
Ingestion API HTTP POST request | 16 KB (text field); 4 MB per HTTP Post request |
Integrations | |
vRealize Operations Manager | 1 |
vSphere vCenter Server | 15 per node |
Active Directory domains | 1 |
Email servers | 1 |
DNS servers | 2 |
NTP servers | 4 |
Forwarders | 10 |