When you configure vRealize Log Insight, you must stay at or below the supported maximums.
| Item | Maximum |
|---|---|
| Node Configuration | |
| CPU | 16 vCPUs |
| Memory | 32 GB |
| Storage device (vmdk) | 2 TB - 512 bytes |
| Total addressable storage | 4 TB (+ OS drive) A maximum of 4 TB addressable log storage on Virtual Machine Disks (VMDKs) with a maximum size of 2 TB each. You can have two 2 TB VMDKs or four 1 TB VMDKs, and so on. When you reach the maximum, you must scale outward with a larger cluster size instead of adding more disks to existing VMs. |
| Syslog connections | 750 |
| Cluster Configuration | |
| Nodes | 18 (Primary + 17 Workers) |
| Virtual IP addresses | 12 |
| Ingestion per Node | |
| Events per second | 15,000 eps |
| Syslog message length | 10 KB (text field) |
| Ingestion API HTTP POST request | 16 KB (text field); 4 MB per HTTP Post request |
| Integrations | |
| vRealize Operations | 1 |
| vSphere vCenter Server | 15 per node |
| Active Directory domains | 1 |
| Email servers | 1 |
| DNS servers | 2 |
| NTP servers | 4 |
| Forwarders | 10 |
| Data Partition Configuration | |
| Data partitions | 5 |