NSX-T 和 NSX for vSphere 設定中的所有邏輯路由器介面都具有相同的 MAC 位址 (02:50:56:56:44:52)。從 NSX-T Data Center 3.0.2 開始,您可以在 NSX-T 中變更此位址,以避免在將虛擬機器從 NSX for vSphere 設定移轉至 NSX-T 設定時發生問題。
變更 MAC 位址涉及進行兩次 API 呼叫。
如果您尚未建立任何傳輸節點,請進行下列 GET API 呼叫。例如:
GET https://10.40.79.126/api/v1/global-configs/RoutingGlobalConfig Response: { "l3_forwarding_mode" : "IPV4_ONLY", "logical_uplink_mtu" : 1500, "vdr_mac" : "02:50:56:56:44:77", "vdr_mac_nested" : "02:50:56:56:44:52", "allow_changing_vdr_mac_in_use" : true, "resource_type" : "RoutingGlobalConfig", "id" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "display_name" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "_create_user" : "system", "_create_time" : 1595313890595, "_last_modified_user" : "admin", "_last_modified_time" : 1595465694142, "_system_owned" : false, "_protection" : "NOT_PROTECTED", "_revision" : 14 }
接受呼叫的回應、變更
vdr_mac 值,然後使用它進行下列 PUT API 呼叫。例如:
PUT https://10.40.79.126/api/v1/global-configs/RoutingGlobalConfig { "l3_forwarding_mode" : "IPV4_ONLY", "logical_uplink_mtu" : 1500, "vdr_mac" : "02:50:56:56:44:99", "vdr_mac_nested" : "02:50:56:56:44:53", "allow_changing_vdr_mac_in_use" : true, "resource_type" : "RoutingGlobalConfig", "id" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "display_name" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "_create_user" : "system", "_create_time" : 1595313890595, "_last_modified_user" : "admin", "_last_modified_time" : 1595465694142, "_system_owned" : false, "_protection" : "NOT_PROTECTED", "_revision" : 14 } Response: { "l3_forwarding_mode" : "IPV4_ONLY", "logical_uplink_mtu" : 1500, "vdr_mac" : "02:50:56:56:44:99", "vdr_mac_nested" : "02:50:56:56:44:53", "allow_changing_vdr_mac_in_use" : true, "resource_type" : "RoutingGlobalConfig", "id" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "display_name" : "49b261fe-f4e4-46ad-958c-da9cb4271e32", "_create_user" : "system", "_create_time" : 1595313890595, "_last_modified_user" : "admin", "_last_modified_time" : 1595466163148, "_system_owned" : false, "_protection" : "NOT_PROTECTED", "_revision" : 15 }
如果您已建立傳輸節點,請發出相同的 GET 和 PUT API 呼叫,但對於 PUT 呼叫,請將參數 allow_changing_vdr_mac_in_use 設為 true
。