When problems occur in a WDM network, many alarms are generated as a result. For instance, if a fiber goes down inside a network element, there may be an LOS generated at a downstream circuit pack, and up to 80 LOS alarms generated on transponders whose input signals are carried by the fiber. If wavelengths have been added and dropped along the light path, these alarms can occur at various point across the network. The Optical Transport Manager uses the local LOS alarm as a symptom of the root-cause problem (WdmLink Down) and identifies the transponder LOS alarms as being impacts of the underlying root-cause problem.

Symptom and impact events lists the events that can appear as symptoms and/or impacts of root-cause notifications.

Table 1. Symptom and impact events

Object

Event

Description

TransponderInOcnPort,

TransponderOutOcnPort

LofEvent

Loss of frame

TransponderInFecPort

FecLofEvent

Loss of FEC frame

Any Input Port

LosEvent

Loss of signal

AmpInOtsPort

LocEvent

Loss of continuity

Any Output Port

OutFailEvent

Transmit failed

Any Input/Output Port

SignalDegradeEvent

Signal Degrade

Any Output port of an amp or a transponder

LaserTemperatureEvent

Laser Temperature

Any Output port of an amp or a transponder

LaserBiasEvent

Laser Bias Current Level

AmpOutOtsPort

AprEvent

Automatic Power Reduction

TransponderInFecPort

AisEvent

Forward Defect Indication

TransponderInFecPort

BdiEvent

Backward Defect Indication

AmpOutOtsPort

ForcedShutdownEvent

Forced Laser shutdown

Any Card

CardRemovalEvent

Improper Removal

AmpOutOtsPort

AmpOutOmsPort

ReflectionEvent

Reflection Power

AmpOutOtsPort

AmpOutOmsPort

ShutdownEvent

Laser shutdown

Any Card

CardFailureEvent

Replaceable Unit Problem

AmpOutOscPort

AmpInOscPort

The DCC card (e.g., AUXA)

DccFailureEvent

DCC Failure

OC192_TransmitTransponder_NEC64

OCHTRemovedEvent

OCLTRemovedEvent

FECTRemovedEvent

Improper Removal

OC192_TransmitTransponder_NEC64

OCHTFailedEvent

OCLTFailedEvent

FECTFailedEvent

Transmit Failed

OC192_TransmitTransponder_NEC64

OCLTToFECTLinkFailedEvent

FECTToOCHTLinkFailedEvent

Internal Link Failure

OC192_ReceivetTransponder_NEC64

OCHRRemovedEvent

OCLRRemovedEvent

FECRRemovedEvent

Improper Removal

OC192_ReceivetTransponder_NEC64

OCHRFailedEvent

OCLRFailedEvent

FECRFailedEvent

Transmit Failed

OC192_ReceivetTransponder_NEC64

OCHRToFECRLinkFailedEvent

FECRToOCLRLinkFailedEvent

Internal Link Failure