This threshold setting configures the monitoring of a Nortel Call Manager’s standby state. Parameters for the VoIP Nortel Backup Monitoring Options setting lists the parameters for the VoIP Nortel Backup Monitoring Options threshold setting.

Table 1. Parameters for the VoIP Nortel Backup Monitoring Options setting

Parameter

Default value

Description

StandBy_Reset_Mode

true,false

Default: false

Applicable to failover and to the active Nortel Call Manager that is now in Standby mode:

Controls whether VoIP Availability Manager transitions the Standby state of the Call Manager from TRUE to FALSE when the time specified in the Standby_Reset_Time_AtSec parameter expires.

  • True enables the automatic transitioning.

  • False disables the automatic transitioning.

This parameter is used to clear the Call Manager Down notification (resulting from Standby = TRUE) when no trap is received to clear the notification.

Standby_Reset_Time_AtSec

240 seconds

(4 minutes)

Specifies the Call Manager’s Standby = TRUE time, in seconds, after which VoIP Availability Manager transitions the Standby state to FALSE.