Default values for W4NServer Polling setting parameters lists the W4NServer Polling setting parameters.

Table 1. Default values for W4NServer Polling setting parameters

Parameter

Default value

Description

AnalysisMode

Enabled

Enables or disables analysis. No polling is performed if analysis is disabled.

PollingInterval

305

The polling interval, in seconds. It should be greater than the minimum polling interval configured in EMC M&R SolutionPacks.

Retries

2

The number of times to retry a failed poll request. It should be greater than the minimum polling interval configured in EMC M&R SolutionPacks.

This can be used as the number of polling interval data required from EMC M&R during polling.

For example, the value of Retries= 2 means that Server Manager is asking EMC M&R for data from the past two polling cycles during monitoring.

This is done to overcome the EMC M&R server failing to poll devices for one polling cycle.

If EMC M&R fails to poll, it does not update the database for that polling cycle, but being queried, EMC M&R failed to provide any error for that polling interval.

Time-out

700

The value, in milliseconds, for a poll request to time.