The VRF SNMP Setting determines the polling intervals that are used by MPLS Manager to monitor VRFs. MPLS Manager monitors the VRFs by probing the SNMP tables on the PE or multi-VRF CE devices that are hosting the VRFs.
VRF SNMP Setting parameters and their values lists the VRF SNMP Setting parameters.
Parameter |
Values |
Description |
---|---|---|
AnalysisMode |
ENABLED,DISABLED Default: ENABLED |
Enables or disables:
|
PollingInterval |
30 to 3600 seconds Default: 240 seconds |
Sets the time between successive polls. |
Retries |
0 to 10 retries Default: 3 |
Sets the number of retry polls to perform when the initial poll fails. |
Timeout |
10 to 10000 milliseconds Default: 700 milliseconds |
Sets the amount of time to wait for the poll response before the first poll request times out. The timeout value doubles for each successive retry. For Timeout=700 msec (0.7 sec) and Retries=3:
|
For the VRF SNMP Setting, MPLS Manager uses the values polled from the discovered PE or multi-VRF CE devices when analyzing VRFs, including the values for MaxRoutes and MidRouteThreshold.