Events and thresholds for Temperature and Voltage sensors gives the default threshold setting and events generated for temperature and voltage sensors.

Table 1. Events and thresholds for Temperature and Voltage sensors

Event

Utilization threshold

Description of threshold

Default value

Condition

OutOfRange

RelativeTemperature

How close the current temperature value can be to the value that triggers an emergency shutdown, expressed as a percentage of the emergency shutdown value.

10%

Range: 0 to 100%

If the shutdown temperature is 50 degrees C and the RelativeTemperatureThreshold is 10%, the OutOfRange event is notified if the temperature exceeds 45 degrees C.

OutOfRange

TemperatureHigh Threshold

High threshold value of the temperature sensor, in degrees C.

50 degrees C

Range: 0 to 100 degrees C

This event is generated when the temperature exceeds the configured threshold value.

OutOfRange

RelativeVoltage Threshold

How close the current voltage value can be to the value that triggers an emergency shutdown, expressed as a percentage of the emergency shutdown value. For example, if the shutdown temperature is 50 degrees C, and the RelativeTemperatureThreshold is 10%, the OutOfRange event is notified if the temperature exceeds 45 degrees C.

0 %

Range: 0 to 5%

If the shutdown value is +30V, and the RelativeVoltageThreshold is 10%, the OutOfRange event is notified if the voltage exceeds +27V.

OutOfRange

VoltageSensorHigh Threshold

High threshold value of the voltage sensor test point, in volts.

5 volts

0 to 100 volts

This event is generated when the voltage exceeds the configured threshold value.

OutOfRange

VoltageSensorLow Threshold

Low threshold value of the voltage sensor test point, in volts.

1 volt

0 to 100 volts

This event is generated when the voltage exceeds the configured threshold value.

StateNotNormal

N/A

N/A

N/A