In VMware Cloud Foundation, to provide tenant workloads with routing, services, and connectivity to networks that are external to the workload domain, deploy a pair of NSX-T Edge nodes in each availability zone.
You repeat this procedure to deploy four NSX-T Edge nodes.
Table 1.
NSX-T Edge Nodes
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Value for sfo02wesg01 |
Value for sfo02wesg02 |
Network 3 |
sfo01-w-nvds01-uplink02 |
sfo01-w-nvds01-uplink02 |
sfo02-w-nvds01-uplink02 |
sfo02-w-nvds01-uplink02 |
Network 2 |
sfo01-w-nvds01-uplink01 |
sfo01-w-nvds01-uplink01 |
sfo02-w-nvds01-uplink01 |
sfo02-w-nvds01-uplink01 |
Network 1 |
sfo-w-overlay |
sfo-w-overlay |
sfo-w-overlay |
sfo-w-overlay |
Network 0 |
ls-sfo01w01vc01-shared01-management |
ls-sfo01w01vc01-shared01-management |
sfo02-w-nvds01-management |
sfo02-w-nvds01-management |
Management IP address |
172.16.41.21 |
172.16.41.22 |
172.16.61.21 |
172.16.61.22 |
Default gateway |
172.16.41.253 |
172.16.41.253 |
172.16.61.253 |
172.16.61.253 |
Prerequisites
Download the
.ova file for the NSX-T Edge 2.5 appliance for VMWare ESXi from My VMware.
Procedure
- In a Web browser, log in to vCenter Server by using the vSphere Client.
Setting |
Value |
URL |
https://sfo01m01vc01.sfo01.rainpole.local/ui |
User name |
[email protected] |
Password |
vsphere_admin_password |
- In the Hosts and Clusters inventory, expand the sfo01w01vc01.sfo01.rainpole.local tree and expand the sfo01-w01dc data center.
- Expand the sfo01-w01-shared01 cluster.
- Right-click the sfo01-w01rp-sddc-edge resource pool and select Deploy OVF template.
- On the Deploy OVF template page, navigate to the .ova file of the NSX-T Edge appliance and click Next.
- On the Select name and folder page, configure the settings and click Next.
Setting |
Value |
Name |
sfo01wesg01 |
Folder or data center |
sfo01-w01fd-nsx |
- On the Select a compute resource page, select the sfo01-w01rp-sddc-edge resource pool and click Next.
- On the Configuration page, select Medium and click Next.
- On the Select storage page, select sfo-w01-vsan and click Next.
- On the Select networks page, configure the settings and click Next.
Source Network |
Destination Network |
Network 3 |
sfo01-w-nvds01-uplink02 |
Network 2 |
sfo01-w-nvds01-uplink01 |
Network 1 |
sfo-w-overlay |
Network 0 |
sfo01-w-nvds01-management |
- On the Customize template page, configure the settings, and click Next.
Setting |
Value |
System Root User Password / Confirm Password |
nsx_edge_root_password |
CLI "admin" User Password / Confirm Password |
nsx_edge_admin_password |
CLI "audit" User Password / Confirm Password |
nsx_edge_audit_password |
Hostname |
sfo01wesg01.sfo01.rainpole.local |
Default IPv4 Gateway |
172.16.41.253 |
Management Network IPv4 Address |
172.16.41.21 |
Management Network Netmask |
255.255.255.0 |
DNS Server List |
|
Domain Search List |
sfo01.rainpole.local |
NTP Server List |
ntp.sfo01.rainpole.local |
Enable SSH |
Selected |
Allow root SSH login |
Deselected |
- On the Ready to complete page, click Finish.
- After the deployment finishes, power on the NSX-T Edge appliance.
- In the VMs and Templates inventory, expand the sfo01w01vc01.sfo01.rainpole.local tree.
- Expand the sfo01-w01fd-nsx folder, right-click the sfo01wesg01 virtual machine, and select .
- Repeat this procedure to deploy the other NSX-T Edge appliances.