Create the segments to connect nodes that send VLAN and overlay traffic in the NSX-T workload domain in VMware Cloud Foundation.

During the deployment of the NSX-T workload domain, SDDC Manager creates a default configuration of network segments.
Table 1. NSX-T Logical Networks Available After Workload Domain Deployment
Segment Name Connected Gateway & Type Transport Zone VLAN
ls-sfo01w01vc01-shared01-management None vlan-tz-UUID 1641
ls-sfo01w01vc01-shared01-vmotion None vlan-tz-UUID 1642
ls-sfo01w01vc01-shared-vsan None vlan-tz-UUID 1643
net-overlay-UUID None overlay-tz-UUID 0-4094
You add the segments that are required for the network connectivity in the NSX-T workload domain with multiple availability zones and assign each uplink segments an uplink port.
Table 2. New NSX-T Logical Networks in the Workload Domain
Segment Name Connected Gateway & Type Transport Zone VLAN
sfo01-w-nvds01-uplink01 None vlan-tz-UUID 0-4094
sfo01-w-nvds01-uplink02 None vlan-tz-UUID 0-4094
sfo01-w-uplink01 None sfo01-w-uplink01 1647
sfo01-w-uplink02 None sfo01-w-uplink02 1648
sfo02-w-nvds01-management None vlan-tz-UUID 1661
sfo02-w-nvds01-vmotion None vlan-tz-UUID 1662
sfo02-w-nvds01-vsan None vlan-tz-UUID 1663
sfo02-w-nvds01-uplink01 None vlan-tz-UUID 0-4094
sfo02-w-nvds01-uplink02 None vlan-tz-UUID 0-4094
sfo02-w-uplink01 None sfo01-w-uplink01 1667
sfo02-w-uplink02 None sfo01-w-uplink02 1668
sfo-w-overlay None vlan-tz-UUID 0-4094

Procedure

  1. In a Web browser, log in to the user interface of NSX-T Manager.
    Setting Value
    URL https://sfo01wnsx01.sfo01.rainpole.local
    User name admin
    Password nsx_admin_password
  2. On the main navigation bar, click Networking.
  3. In the navigation pane, select Segments.
  4. On the Segments tab, click Add Segment.
  5. Configure the values for the sfo02-w-nvds01-management segment and click Save.
    Setting Value
    Name sfo02-w-nvds01-management
    Connected Gateway & Type None
    Transport Zone vlan-tz-UUID
    VLAN 1661
  6. Repeat this step to create the remaining segments.
  7. Change the teaming policy for the uplink segments for the NSX-T Edge nodes.
    1. On the main navigation bar, click Advanced Networking and Security.
    2. Under Networking, click Switching.
    3. Select the uplink segment, click Edit and configure the following uplink teaming policy.
      Uplink Segment Uplink teaming policy name
      sfo01-w-nvds01-uplink01 Uplink01
      sfo01-w-nvds01-uplink02 Uplink02
      sfo02-w-nvds01-uplink01 Uplink01
      sfo02-w-nvds01-uplink02 Uplink02