The following table describes the VNF-C configuration details:
Parameter |
Value |
Configuration |
---|---|---|
Virtual CPU |
||
Reservation |
Maximum per number of vCPU allocated to VM |
Go to VM Settings > Virtual Hardware > CPU > Reservation. Set the value to number of vCPUs multiplied by processor base frequency. |
Memory |
||
Shares |
High |
Go to VM Settings > Virtual Hardware > Memory > Shares. Set the value to High. |
Reservation |
Maximum Necessary |
Go to VM Settings > Virtual Hardware > Memory > Reservation. Set the value to Maximum, as required. |
Limit |
Unlimited |
Go to VM Settings > Virtual Hardware > Memory > Limit. Set the value to Unlimited. |
VM-level Configuration |
||
Hardware Version |
Version 15 for ESXi 6.7U2/U3 |
Right-click the VM, select Compatibility > Upgrade VM Compatibility. |
Virtual NIC for Data Plane Interfaces |
VMXNET3 |
Set VMXNET3 as the vNIC adapter type. |
Latency Sensitivity |
Set to High |
Go to Edit Settings > VM Options > Advanced > Configuration Parameters. Set sched.cpu.latencySensitivity = high. |
Huge Pages |
Set to TRUE. |
Go to Edit Settings > VM Options > Advanced > Configuration Parameters. Set sched.mem.lpage.enable1GPage = TRUE. |