The following table describes the VNF-C configuration details:

Parameter

Value

Configuration

Virtual CPU

Reservation

Maximum per number of vCPU allocated to VM

Go to VM Settings > Virtual Hardware > CPU > Reservation.

Set the value to number of vCPUs multiplied by processor base frequency.

Memory

Shares

High

Go to VM Settings > Virtual Hardware > Memory > Shares.

Set the value to High.

Reservation

Maximum Necessary

Go to VM Settings > Virtual Hardware > Memory > Reservation.

Set the value to Maximum, as required.

Limit

Unlimited

Go to VM Settings > Virtual Hardware > Memory > Limit.

Set the value to Unlimited.

VM-level Configuration

Hardware Version

Version 15 for ESXi 6.7U2/U3

Right-click the VM, select Compatibility > Upgrade VM Compatibility.

Virtual NIC for Data Plane Interfaces

VMXNET3

Set VMXNET3 as the vNIC adapter type.

Latency Sensitivity

Set to High

Go to Edit Settings > VM Options > Advanced > Configuration Parameters.

Set sched.cpu.latencySensitivity = high.

Huge Pages

Set to TRUE.

Go to Edit Settings > VM Options > Advanced > Configuration Parameters.

Set sched.mem.lpage.enable1GPage = TRUE.